Abbott 1012068-03 Versacore Standard Hi-Torque Guide Wire System 0.035" 145cm

$875.00

Abbott 1012068-03 Versacore Standard Hi-Torque Guide Wire System 0.035" 145cm

$875.00
SKU:
1012068-03
Weight:
3.00 LBS
Shipping:
Calculated at checkout
Quantity:

Out of Stock

Share

Product Description

Abbott 1012068-03 Versacore Standard Hi-Torque Guide Wire System 0.035"  145cm.  Box of 5.

The Hi-Torque Versacore is a peripheral 0.035 guide wire designed for routine diagnostic and device delivery in interventional procedures*. Versacore features a soft, shapeable tip to provide safe access to peripheral lesions and superb visibility under fluoroscopy. Versacore also offers excellent torque responses, enabling the device to move consistently and easily around the bends of a patient's vascular system, even when accessing hard-to-reach lesions.

INDICATIONS

The Hi-Torque Steerable Guide Wire is intended for use in angiographic procedures to introduce and position diagnostic and interventional devices within the peripheral vasculature during percutaneous procedures. The wire can be torqued to facilitate navigation through tortuous vessels.

 The Hi-Torque Steerable Guide Wire is not intended for use in the coronary or neurovasculature.

 

CONTRAINDICATIONS

The Hi-Torque Steerable Guide Wire is not intended for use in the coronary or neurovasculature.

 

 WARNINGS

This device is designed and intended for ONE TIME USE ONLY. DO NOT RESTERILIZE AND / OR REUSE.

 Observe all guide wire movement in the vessels. Before a guide wire is moved or torqued, the tip movement should be examined under fluoroscopy. Do not torque a guide wire without observing corresponding movement of the tip; otherwise, vessel trauma may occur.

 Torquing a guide wire against resistance may cause guide wire damage and / or guide wire tip separation. Always advance or withdraw the guide wire slowly. Never push, auger, withdraw, or torque a guide wire which meets resistance. Resistance may be felt and / or observed under fluoroscopy by noting any buckling of the guide wire tip. Determine the cause of resistance under fluoroscopy and take any necessary remedial action.

 If the wire tip becomes entrapped within the vasculature, DO NOT TORQUE THE GUIDE WIRE.

 Maintain continuous flush while removing and reinserting the guide wire to prevent air from entering the catheter system. Perform all exchanges slowly to prevent air entry and / or trauma. Wipe the wire before all exchanges.

 When reintroducing the guide wire, confirm that the interventional device tip is free within the vessel lumen and not against the vessel wall. Failure to do so may result in vessel trauma upon guide wire exit from the device. Use the radiopaque marker of the interventional device to confirm position.

 

PRECAUTIONS

Guide wires are delicate instruments and should be handled carefully. Prior to use and when possible during the procedure, inspect the guide wire carefully for bends, kinks, or other damage. Do not use damaged wires. Using a damaged wire may result in vessel damage and / or inaccurate torque response.

 Confirm the compatibility of the guide wire diameter with the interventional device before actual use.

 